Coolstar home

Coolstar Coldheads

Coolstar Compressors

Coolstar Cryopumps

Find Product: Go
Coolstar

Coolstar Coldheads

Features Specifications What's new? Downloads

 

Coolstar 0/12

Coolstar 0/40

Coolstar 2/9

Coolstar 6/30

Nominal cooling power at 20K (W)

Normal speed (50 Hz) 72 rpm

2.0

6.0

Normal speed (60 Hz) 72 rpm

2.1

6.5

Boost speed 90 rpm

2.4

7.0

Standby speed 45 rpm

1.1

4.0

 

Nominal cooling power at 77K (W)

Normal speed (50 Hz) 72 rpm

12.0

42.0

8.5

26.0

Normal speed (60 Hz) 72 rpm

14.5

50.0

9.5

28.0

Boost speed 90 rpm

17.0

57.0

11.0

30.0

Standby speed 45 r pm

8.0

27.0

6.2

17.0

Crossover (mbar l at 20K)

75

120

220

500

 

Time to cooldown bare cold head (min)

to 20K

<16

<18

to 77K

<11

<11

 

Increase in cooldown time for each 100g added mass (min)

 

6

2

14

5.2

       

Base temperature (K)

 

 

 

Normal speed

26

22

9.0

9.0

Boost speed

25

18

8.5

8.5

Service intervals (hours)

>15,000

>15,000

>15,000

>15,000

Weight (kg)

2.4

5.6

2.5

6.1